• Pay Bill
  • Customer Support
  • Contact
  • Emergencies

Standard Drawings

Table of Contents

Note: These Drawings are provided for standardization purposes only. They represent minimum design standards which may require upgrading for specific applications.

 
Number Title
1 Water Distribution System – Typical Plan
2 Typical Street Cross Section and Street Centerline Profile
3 Typical Street Cross Section – Public Street
4 Typical Street Cross Section – Private Street
5 Water Distribution System – Typical Plan for Curved Streets
6 Water Distribution System – Typical Plan for Cul-de-Sacs
7 Plan, Profile & Locations for Fire Hydrants, Mains and Valves
8 Piping at Street Intersections – Future Connections
9 Typical Quarter Section Hydraulic Grid System
10 Typical Trench Section – Pipe Protection
11 Typical Trench Section for Pipelines in Dipping Bedrock
12 Blowoff Installation for 12 Inch and Smaller Pipe
13 Transmission Main Blowoff Installation
14 Permanent 2-Inch Blowoff in 48-Inch Manhole
15 Valve Box Support Plate and Valve Operator Extension Guide
16 2-Inch Air Valve Assembly
17 Air Valve Assembly with Access Manhole
18 Conduit or Transmission Main, Mechanical Joint or Flanged Butterfly Valve Installation
19 Concrete Kickblocks – Bearing Surfaces & Installation
20 Concrete Kickblocks
21 Length of Restrained Pipe
22 Tie Rod and Washer Details
23 Tie Rod Coupling
24 Flange Lug Detail
25 Clamp Details & Dimensions for use with CI & DI Fittings Only
26 Combination Flanged Harness Lug Details
27 Mechanical Joint Restraint Details
28 Joint Restraint Detail
29 Bored Crossings Beneath Conduits
30 Bore Casing Detail
31 Open Cut Crossing Beneath Conduit or Conflicting Utility
32 Crossing Storm and Sanitary Sewers
33 Reference Post-Typical Detail
34 Typical Cutoff Wall for Ditch or Canal Crossing
35 2 Inch and Larger Domestic and Fireline Connections
36 Fireline Connection with Domestic Service Tee
37 Insulated Joints, Rods, and Bolted Sleeve Type Couplings
38 Polyethylene Wrap
39 Pipe Joint Bonding
40 Adjustable Steel Pipe Valve Support
41 Industrial Vent Assembly – Installation and Details
42 Industrial Vent Assembly – Vent Screen
43 Residential Vent Assembly
44 Pressure Regulating Valve – Manhole Installation Typical Plan
45 Pressure Regulating Valve – Manhole Installation Cross Section
46 Pressure Regulating Valve – Rectangular Vault Typical Plan
47 Pressure Regulation Valve – Rectangular Vault Cross Section
48 General Meter Notes
49 Service Line, Stop Box and Outside Meter Installation
50 Outside Setting for 3/4 Inch & 1 Inch Meters
51 Service Line, Stop Box and Inside Meter Installation for 3/4 Inch and 1 Inch Meters
52 Typical Inside Setting for 3/4 Inch and 1 Inch Meter with AMR (Isometric View and Elevation)
53 Typical Inside Setting for 3/4 Inch and 1 Inch Meter with AMR
54 Inside Meter Setting and Remote AMR Installation for Home Built on Slab
55 Remote AMR Device Installation on Outside Building Wall
56 Outside Setting for 1-1/2 Inch and 2 Inch Meter with Check Valve and Bypass in Manhole
57 Inside Setting for 1-1/2 Inch & 2 Inch Meter with Check Valve & Bypass
58 Wall Plates for Meters 3 Inches and Larger
59 Inside Setting for 3 Inch and Larger Meter
60 Meter in Vault with Bypass
61 Meter and Vault Dimensions
62 Large Meter in Vault
63 Instrumentation and Control Ladder Diagram – Typical
64 Instrumentation and Control Wiring Diagram – Typical
65 Instrumentation and Control Cabinet Layout – Typical
66 Instrumentation and Control Detail and Schedules – Typical
67 Instrumentation and Control P & ID – Typical
68 Instrumentation and Control Site Diagram – Typical
69 Stub-Out Configurations for Future Main Extensions
70 Valve Operation
71 Outside Setting for 1-1/2 Inch & 2 Inch Irrigation Meter in Vault
72 Master Meter for Emergency Interconnection Plans
73 Master Meter for Emergency Interconnection Details and Dimensions
74 Above Ground Dual System Interconnection
75 Below Ground Dual System Interconnection
76 Single Feed System Interconnection
77 Standard Design for Hydrant Interconnection
78 Pitot Installation & Typical Conc MH Installation
79 Standard Design for Hydrant Meter Installation
80 Standard Design for Blowoff Hydrant
81 Tracer Wire Installation for PVC Water Main
82 Traffic Impediment Bollard
83 Submerged BFV with Torque Tube and Actuator Stand
84 Recycled Water System Pentagon Operating Nut
Number Title
1 Water Distribution System – Typical Plan
2 Typical Street Cross Section and Street Centerline Profile
3 Typical Street Cross Section – Public Street
4 Typical Street Cross Section – Private Street
5 Water Distribution System – Typical Plan for Curved Streets
6 Water Distribution System – Typical Plan for Cul-de-Sacs
7 Plan, Profile & Locations for Fire Hydrants, Mains and Valves
8 Piping at Street Intersections – Future Connections
9 Typical Quarter Section Hydraulic Grid System
10 Typical Trench Section – Pipe Protection
11 Typical Trench Section for Pipelines in Dipping Bedrock
12 Blowoff Installation for 12 Inch and Smaller Pipe
13 Transmission Main Blowoff Installation
14 Permanent 2-Inch Blowoff in 48-Inch Manhole
15 Valve Box Support Plate and Valve Operator Extension Guide
16 2-Inch Air Valve Assembly
17 Air Valve Assembly with Access Manhole
18 Conduit or Transmission Main, Mechanical Joint or Flanged Butterfly Valve Installation
19 Concrete Kickblocks – Bearing Surfaces & Installation
20 Concrete Kickblocks
21 Length of Restrained Pipe
22 Tie Rod and Washer Details
23 Tie Rod Coupling
24 Flange Lug Detail
25 Clamp Details & Dimensions for use with CI & DI Fittings Only
26 Combination Flanged Harness Lug Details
27 Mechanical Joint Restraint Details
28 Joint Restraint Detail
29 Bored Crossings Beneath Conduits
30 Bore Casing Detail
31 Open Cut Crossing Beneath Conduit or Conflicting Utility
32 Crossing Storm and Sanitary Sewers
33 Reference Post-Typical Detail
34 Typical Cutoff Wall for Ditch or Canal Crossing
35 2 Inch and Larger Domestic and Fireline Connections
36 Fireline Connection with Domestic Service Tee
37 Insulated Joints, Rods, and Bolted Sleeve Type Couplings
38 Polyethylene Wrap
39 Pipe Joint Bonding
40 Adjustable Steel Pipe Valve Support
41 Industrial Vent Assembly – Installation and Details
42 Industrial Vent Assembly – Vent Screen
43 Residential Vent Assembly
44 Pressure Regulating Valve – Manhole Installation Typical Plan
45 Pressure Regulating Valve – Manhole Installation Cross Section
46 Pressure Regulating Valve – Rectangular Vault Typical Plan
47 Pressure Regulation Valve – Rectangular Vault Cross Section
48 General Meter Notes
49 Service Line, Stop Box and Outside Meter Installation
50 Outside Setting for 3/4 Inch & 1 Inch Meters
51 Service Line, Stop Box and Inside Meter Installation for 3/4 Inch and 1 Inch Meters
52 Typical Inside Setting for 3/4 Inch and 1 Inch Meter with AMR (Isometric View and Elevation) 
53 Typical Inside Setting for 3/4 Inch and 1 Inch Meter with AMR
54 Inside Meter Setting and Remote AMR Installation for Home Built on Slab
55 Remote AMR Device Installation on Outside Building Wall
56 Outside Setting for 1-1/2 Inch and 2 Inch Meter with Check Valve and Bypass in Manhole
57 Inside Setting for 1-1/2 Inch & 2 Inch Meter with Check Valve & Bypass
58 Wall Plates for Meters 3 Inches and Larger
59 Inside Setting for 3 Inch and Larger Meter
60 Meter in Vault with Bypass
61 Meter and Vault Dimensions
62 Large Meter in Vault
63 Instrumentation and Control Ladder Diagram – Typical
64 Instrumentation and Control Wiring Diagram – Typical
65 Instrumentation and Control Cabinet Layout – Typical
66 Instrumentation and Control Detail and Schedules – Typical
67 Instrumentation and Control P & ID – Typical
68 Instrumentation and Control Site Diagram – Typical
69 Stub-Out Configurations for Future Main Extensions
70 Valve Operation
71 Outside Setting for 1-1/2 Inch & 2 Inch Irrigation Meter in Vault
72 Master Meter for Emergency Interconnection Plans
73 Master Meter for Emergency Interconnection Details and Dimensions
74 Above Ground Dual System Interconnection
75 Below Ground Dual System Interconnection
76 Single Feed System Interconnection
77 Standard Design for Hydrant Interconnection
78 Pitot Installation & Typical Conc MH Installation
79 Standard Design for Hydrant Meter Installation
80 Standard Design for Blowoff Hydrant
81 Tracer Wire Installation for PVC Water Main
82 Traffic Impediment Bollard
83 Submerged BFV with Torque Tube and Actuator Stand
84 Recycled Water System Pentagon Operating Nut